FEATURES:
- Frequency and period measurement
- 1Hz to 120MHz range
- 8 Digit display (0.3" LED)
- Over-flow indicator
- 15m Vrms high sensitivity
- 5PPM high stability time base
- Low pass filter function
SPECIFICATIONS:
- Display: 8 Digit with Hz, kHz, MHz, S, mS, µS, nS & overflow
- Gate Time: 0.1S, 1S, 10S switch selectable
- Accuracy: ±(1 digit + time base accuracy)
- Input:
•Sensitivity: 10Hz~10MHz < 15m Vrms, 10MHz~40MHz < 20m Vrms, 40MHz~80MHz < 35m Vrms, 80MHz~120MHz < 50m Vrms
•Input Impedance: 1MW//35pF
•Coupling System: AC Coupling
•Max Input Volt: 150Vrms
- Time Base:
•Oscillation Frequency: 10MHz
•Aging Rate: ±1PPM per month
•Temp. Stability: 25°C ± 5°C: ±5PPM
- Resolution: The max. resolution is 1µHz for 10Hz & 0.1Hz for 100MHz. Input respectively for frequency measurement & 1nS for 10Hz & 0.1 x 10-15 for 100MHz.
- Power Source: AC 100V/120V/230V ±10%, 50/60Hz
- Accessories: Power cord x 1, Instruction manual x 1, Test lead GTL-101 x 1
- Dimensions & Weight: 230 x 95 x 280mm (W x H x D) Approx. 1.7kg |